Product

Engineered for the Well.
Built for Reliable Performance.

Overview

Wells & Waves provides specialised hardware and cable solutions designed for reliable Distributed Fiber Optic Sensing (DFOS) in demanding downhole environments. Our current product portfolio includes specialty hybrid DFOS cables, combining optical sensing with electrical functionality, and high-pressure and standard Hybrid and fiber optic termination junction boxes engineered to provide secure, low-loss connectivity from the well to surface instrumentation. Each product is developed around practical field requirements, system integrity and ease of installation.

Our product range is continuing to grow, with additional components being introduced to provide a complete, integrated DFOS solution — from downhole cable to surface connection and interrogation.

Developed Around the Field

01
Practical field requirements
02
System integrity
03
Ease of installation

A Growing, Integrated DFOS Solution

Additional components are being introduced to provide a complete, integrated solution across the full sensing chain.

Downhole cable Surface connection Interrogation

Our Services

End-to-end Distributed Fiber Optic Sensing, from first design through to data you can act on.

Semi-permanent DFOS installation

Semi-Permanent Installations

Installations of this type are the backbone of many brownfield wells where instrumentation is required. The instrumentation can be retrieved — and in some cases re-used — whenever a work-over of the production tubing is carried out.

Read More
Permanent fiber optic installation

Permanent Installation

For unconventional and monitoring wells this approach is adopted. Wells & Waves offers integrated permanent fiber optic installation solutions. Designed for durability and data integrity across the full production lifecycle, from cementing to abandonment.

Read More
Modular DFOS hardware

Modular DFOS Hardware

The strength and distinctive advantage of the WnW solution lies in its modular design philosophy. Everything is scalable, yet flexible enough to be configured for specific, one-off applications.

Read More
Well diagnostics

Well Diagnostics

Demonstrating well integrity is frequently a statutory obligation and often a prerequisite to production. Yet integrity can deteriorate over time and must be monitored.

Read More
DFOS data analytics

Data Analytics

Wells & Waves has the ability to use both standard and proprietary software to integrate multiple data sets and present a holistic picture of the downhole environment.

Read More
Field services and training

Field Services and Training

Equipment alone — whether installation hardware or deployed tools — does not guarantee a successful outcome. The real differentiator is the quality of the personnel on the job. We deliver both: high-performance equipment, and personnel who are fully trained for the safe installation of the systems, using the right tooling for the right task.

Read More

Developed Around the Field

01
Practical field requirements
02
System integrity
03
Ease of installation
01Coiled Tubing · Hybrid Electro-Optical

CT Injection Hybrid Cable 4.0 × 0.30 mm tube

4.0 × 0.30 mm tube · 316L or Alloy 825 · 1 × 1.5 mm² Cu + 4 hermetic fibres · 180 °C (356 °F)

CTH-4.0×0.3-{316L|825}-2SM(H)/2MM(H)-1×1.5-180Rev A · 08 Oct 2026
CT Injection Hybrid Cable — illustration
Illustration · Ø 4.00 mm · not to scale
Overall diameter4.0 ± 0.1 mm0.157 ± 0.004 in
Operating temperature−40 … +180 °C(−40 … +356 °F)
Rated voltage1 200 V DC 
Fibres2 SM + 2 MMhermetic, 180 °C (356 °F)

Applications

  • Coiled-tubing deployment
  • Distributed sensing (DAS, DSS, DTS)
  • Signal transmission from downhole tools
  • Power supply to downhole tools
  • Sour & acid service (Alloy 825)

Construction

Protection tube · return316L or Alloy 825 · OD 4.00 · ID 3.40 · wall 0.30 mm
InsulationFEP fluoropolymer · wall 0.60 mm
Conductor14 × 0.38 mm Cu · 1.5 mm² (≈ AWG 16) · served over FIMT
FIMTAISI 304 · gel filled · OD 1.40 · ID 1.10 mm
Fibres2 × SM(H) + 2 × MM(H) · HT acrylate + hermetic · SM blue, yellow · MM green, natural

Mechanical

316LAlloy 825
Cable weight59 kg/km†40 lb/kft60 kg/km†40 lb/kft
Rated tensile strength3.0 kN†674 lbf3.4 kN†764 lbf
Max. operating tension1.5 kN†337 lbf1.7 kN†382 lbf
Rated collapse pressure815 bar†11 820 psi1 075 bar†15 590 psi
Min. bend radius, no load60 mm†2.36 in
Min. sheave Ø at max. op. tension500 mm†19.7 in

Electrical

316LAlloy 825
R dc conductor @ 20 °C (68 °F)12.5 Ω/km3.81 Ω/kft
R dc tube (return) @ 20 °C (68 °F)212 Ω/km†64.7 Ω/kft324 Ω/km†98.8 Ω/kft
Loop R @ 20 °C (68 °F)225 Ω/km†68.5 Ω/kft337 Ω/km†102.6 Ω/kft
Insulation resistance> 730 MΩ·km†> 2395 MΩ·kft
Capacitance≈ 260 pF/m†≈ 79 pF/ft
Characteristic impedance Z₀≈ 18 Ω†

Optical

SM(H)MM(H)
ITU-TG.652.D + G.657.A1G.651.1
Attenuation* 1310 | 850 nm0.40 dB/km3.0 dB/km
Attenuation* 1550 | 1300 nm0.26 dB/km1.1 dB/km
Typical useDAS · DSSRaman DTS
  • Coiled-tubing injection: the cable is pumped into the CT reel; the bare tube touches the CT wall, so the tube return runs in parallel with the CT string at earth potential — an isolated return is not available. 316L: lower return resistance; chloride SCC risk above ≈ 60 °C (140 °F); not for HCl acid or sour service. Alloy 825: resistant to chloride SCC, H₂S and acids — preferred for acid stimulation and sour wells.
  • † Calculated by Wells & Waves from geometry and handbook material properties, not yet measured on production cable; mechanical values scaled from the 0.5 mm-wall design. To be qualified.
  • * Local attenuation steps caused by winding on a reel are allowed.
02Coiled Tubing · Hybrid Electro-Optical

CT Injection Hybrid Cable 4.0 × 0.50 mm tube

4.0 × 0.50 mm tube · 316L or Alloy 825 · 1 × 1.5 mm² Cu + 4 hermetic fibres · 180 °C (356 °F)

CTH-4.0×0.5-{316L|825}-2SM(H)/2MM(H)-1×1.5-180Rev A · 08 Oct 2026
CT Injection Hybrid Cable — illustration
Illustration · Ø 4.00 mm · not to scale
Overall diameter4.0 ± 0.1 mm0.157 ± 0.004 in
Operating temperature−40 … +180 °C(−40 … +356 °F)
Rated voltage1 200 V DC 
Fibres2 SM + 2 MMhermetic, 180 °C (356 °F)

Applications

  • Coiled-tubing deployment
  • Distributed sensing (DAS, DSS, DTS)
  • Signal transmission from downhole tools
  • Power supply to downhole tools
  • Sour & acid service (Alloy 825)

Construction

Protection tube · return316L or Alloy 825 · OD 4.00 · ID 3.00 · wall 0.50 mm
InsulationFEP fluoropolymer · wall 0.40 mm
Conductor14 × 0.38 mm Cu · 1.5 mm² (≈ AWG 16) · served over FIMT
FIMTAISI 304 · gel filled · OD 1.40 · ID 1.10 mm
Fibres2 × SM(H) + 2 × MM(H) · HT acrylate + hermetic · SM blue, yellow · MM green, natural

Mechanical

316LAlloy 825
Cable weight71 kg/km†48 lb/kft72 kg/km48 lb/kft
Rated tensile strength4.2 kN†944 lbf5.0 kN1,124 lbf
Max. operating tension2.1 kN†472 lbf2.5 kN562 lbf
Rated collapse pressure1 300 bar†18 850 psi1 850 bar26 830 psi
Min. bend radius, no load60 mm2.36 in
Min. sheave Ø at max. op. tension500 mm19.7 in

Electrical

316LAlloy 825
R dc conductor @ 20 °C (68 °F)12.5 Ω/km3.81 Ω/kft
R dc tube (return) @ 20 °C (68 °F)135 Ω/km†41.0 Ω/kft206 Ω/km†62.8 Ω/kft
Loop R @ 20 °C (68 °F)147 Ω/km†44.8 Ω/kft218 Ω/km†66.5 Ω/kft
Insulation resistance> 520 MΩ·km> 1706 MΩ·kft
Capacitance364 pF/m111 pF/ft
Characteristic impedance Z₀≈ 13 Ω†

Optical

SM(H)MM(H)
ITU-TG.652.D + G.657.A1G.651.1
Attenuation* 1310 | 850 nm0.40 dB/km3.0 dB/km
Attenuation* 1550 | 1300 nm0.26 dB/km1.1 dB/km
Typical useDAS · DSSRaman DTS
  • Coiled-tubing injection: the cable is pumped into the CT reel; the bare tube touches the CT wall, so the tube return runs in parallel with the CT string at earth potential — an isolated return is not available. 316L: lower return resistance; chloride SCC risk above ≈ 60 °C (140 °F); not for HCl acid or sour service. Alloy 825: resistant to chloride SCC, H₂S and acids — preferred for acid stimulation and sour wells.
  • † Calculated by Wells & Waves from geometry and handbook material properties, not yet measured on production cable; Alloy 825 tensile, collapse and weight are supplier data; 316L values scaled assuming an equivalent cold-drawn temper. To be qualified.
  • * Local attenuation steps caused by winding on a reel are allowed.
03Downhole Logging · Hybrid Electro-Optical

Hybrid Wireline Cable 8.20 mm · 316L | N08926

8.20 mm armoured cable · 316L or N08926 (SUPA 75) armour · 1 × Cu serve + 4 fibres · 180 °C (356 °F)

1-H-350D · A711862 (316L) / A711863 (N08926)Rev A · 05 Oct 2026
Hybrid Wireline Cable — illustration
Illustration · Ø 8.20 mm · not to scale
Overall diameter8.20 mm0.323 in
Breaking strength36.56 | 40.9 kN8,200 | 9,200 lbf · 316L | N08926
Operating temperature−40 … +180 °C(−40 … +356 °F)
Rated voltage1 500 V DC 

Applications

  • Well logging
  • Distributed sensing (FBG, BOTDR, DTS)
  • Signal transmission from downhole tools
  • Power supply to downhole tools
  • Sour service (N08926 armour)

Construction

Element A · core316L FIMT OD 1.80 mm (0.071 in) in the axis · 4 fibres (2 SM + 2 MM)
Optical fibres2 × SM 8.3/125/245 µm + 2 × MM 50/125/245 µm · hermetic · colours per TIA-598-C
Conductor · Cu serve16 × AWG14 soft copper · 1.87 mm² · served over the FIMT · tube/armour return
InsulationETFE belt · wall 0.81 mm (0.032 in) · belt OD 3.89 mm (0.153 in)
Element B · armourDual layer · inner 13 × 1.08 mm (0.0425 in) + outer 19 × 1.08 mm · 316L (UNS S31603) or N08926 (SUPA 75)

Physical & mechanical

316L · UNS S31603N08926 · SUPA 75
Weight in air302 kg/km†203 lb/kft303 kg/km†204 lb/kft
Weight in fresh water259 kg/km†174 lb/kft260 kg/km†174 lb/kft
Breaking strength36.56 kN8,200 lbf40.9 kN9,200 lbf
Armour wire BS, inner / outer1.3 kN290 lbf1.5 kN333 lbf
Bend diameter51 cm20 in
PREN, armour alloy≈ 24≈ 42–47

Electrical

316L · UNS S31603N08926 · SUPA 75
R dc Cu serve @ 20 °C (68 °F)10.7 Ω/km3.3 Ω/kft
R dc armour (return) @ 20 °C (68 °F)27.1 Ω/km8.3 Ω/kft29.3 Ω/km8.9 Ω/kft
Insulation resistance @ 500 V DC9 000 MΩ·km30 000 MΩ·kft
Capacitance, conductor – armour322 pF/m98 pF/ft

Optical

SM(H)MM(H)
ITU-TG.652.D + G.657.A1G.651.1
Attenuation* 1310 | 850 nm0.42 dB/km3.00 dB/km
Attenuation* 1550 | 1300 nm0.30 dB/km1.00 dB/km
Typical useFBG · BOTDRRaman DTS
  • Two armour grades, one construction: only the Element B armour alloy differs. 316L for general downhole service; N08926 (SUPA 75) super-austenitic, ~6 % Mo, for sour / high-chloride service (H₂S, CO₂), with higher breaking strength.
  • † Nominal values at 20 °C (68 °F) unless stated. * Local attenuation steps caused by winding on a reel are allowed. Other polymer, steel-grade, fibre and 150 °C (302 °F) fibre options on request.
04Distributed Fibre-Optic Sensing

FBG Array DFOS Cable 6.35 mm · 316L

40-grating quasi-distributed temperature array · Brillouin-ready · 260 °C (500 °F) rated

FBG-ARRAY 160MPa-316L-6.35mm-1SMRev A · 17 Jul 2026EAR99 · HTS 8544.49.3040
FBG Array DFOS Cable — illustration
Illustration · Ø 6.35 mm · not to scale
Overall diameter6.35 mm0.250 in
Collapse pressure160 MPa23 206 psi
Temperature rating260 °C(500 °F)
Gratings in array401512–1585 nm

Applications

  • Quasi-distributed temperature (FBG array)
  • Distributed sensing (BOTDR, BOTDA)
  • High-temperature wells to 260 °C (500 °F)

Construction

Outer armour tube316L stainless · OD 6.35 · ID 4.57 · wall 0.89 mm
FIMT316L stainless · OD 4.0 · ID 3.6 · wall 0.20 mm
Gel filling compoundProprietary high-temp compound · fills FIMT bore and annulus
Optical fibreSM PSC · polyimide · core Ø 9 µm · coating Ø 250 µm · high-temp H₂-resistant

Physical & mechanical

Unit weight143 kg/km96 lb/kft
Tensile breaking force≥ 10 kN≥ 2248 lbf
Collapse pressure160 MPa23 206 psi
Fibre tensile strength689 MPa100 kpsi

Optical — FBG array

Gratings in array40
Wavelength span1512–1585 nm
Mean channel spacing1.85 nm
Wavelength tolerance± 0.3 nm
FWHM · FBG length0.2–0.3 nm · 5 mm

Application

PurposeTemperature (FBG + BOTDR)
BOTDAAvailable with optional second fibre
Lengths, lead-in / lead-outPer order
  • Quasi-distributed temperature sensing along a single strain-free fibre, engineered for combined operation with Brillouin backscatter interrogation.
05Retrievable Wireline & Power Delivery

Retrievable Wireline Cable 14.30 mm · ETFE

Coax signal core + 6 × power conductors · ETFE jacket with embedded GEEIPS steel wires · 150 °C (302 °F) rated

RWC-A711843Rev F · 16 Oct 2026EAR99 · HTS 8544.49.3040
Retrievable Wireline Cable — illustration
Illustration · Ø 14.30 mm · not to scale
Overall diameter14.30 ± 0.28 mm0.563 ± 0.011 in
Breaking strength80 kN18,000 lbf
Unit weight, in air592 kg/km398 lb/kft
Temperature rating150 °C(302 °F)

Applications

  • Retrievable downhole cable
  • Power supply to downhole tools
  • Signal transmission from downhole tools

Construction

Element A · coax core#20 AWG Cu + #18 AWG HD Cu return · ETFE insulated & belted · OD 2.79 mm (0.110 in)
Element B · power (× 6)#14 AWG (2.08 mm²) Cu · ETFE insulated · 1 × red, 5 × natural · layer OD 7.87 mm (0.310 in)
Belt & jacketETFE, natural · belt OD 8.38 ± 0.18 mm · jacket OD 14.30 ± 0.28 mm
Embedded wiresGEEIPS steel wires embedded in the outer ETFE jacket

Mechanical

Breaking strength80 kN18,000 lbf
Recommended working load32.3 kN7,250 lbf
Peak working load @ 0.90 % strain48.0 kN10,800 lbf
Wire min. break strength2.16 kN485 lbf
Recommended bend diameter29 cm11.5 in
Elongation (approx.)0.19 m/km/kN0.83 ft/kft/klbf
Unit weight, in fresh water432 kg/km290 lb/kft

Electrical

Voltage, Element A (coax)900 Vdc
Voltage, Element B (power)1,200 Vdc
Element B / return · B / armour2,500 · 3,000 Vdc
R dc Element A, cdr · return40.3 · 27.2 Ω/km12.3 · 8.3 Ω/kft
R dc Element B · GEEIPS wires9.3 · 5.2 Ω/km2.8 · 1.6 Ω/kft
Insulation resistance @ 500 Vdc, A & B15,000 MΩ·km50,000 MΩ·kft
  • Coaxial signal core with six cabled power conductors under an ETFE belt, in a natural ETFE jacket with embedded GEEIPS wires, for retrievable wireline power delivery and telemetry. Nominal values at 20 °C (68 °F).
06Retrievable Wireline · Power, Telemetry & DFOS

Retrievable Hybrid Wireline Cable 14.30 mm · ETFE + FIMT

Coax signal core + 6 × power conductors + gel-filled FIMT (2 SM + 2 MM) · ETFE jacket with embedded GEEIPS steel wires · 150 °C (302 °F) rated

RWC-A711843-FORev A · 17 Oct 2026
Retrievable Hybrid Wireline Cable — illustration
Illustration · Ø 14.30 mm · not to scale
Overall diameter14.30 ± 0.28 mm0.563 ± 0.011 in
Breaking strength80 kN18,000 lbf
Fibres2 SM + 2 MMin gel-filled 316L FIMT
Temperature rating150 °C(302 °F)

Applications

  • Retrievable downhole cable
  • Distributed sensing (DTS, DAS, DSS)
  • Power supply to downhole tools
  • Signal transmission from downhole tools

Construction

Element A · coax core#20 AWG Cu + #18 AWG HD Cu return · ETFE insulated & belted · OD 2.79 mm (0.110 in)
Element B · power (× 6)#14 AWG (2.08 mm²) Cu · ETFE insulated · 1 × red, 5 × natural · layer OD 7.87 mm (0.310 in)
Element C · FIMT316L · OD 0.95 / ID 0.75 mm† · H₂-resistant high-temp gel · between two Element B conductors, r = 3.71 mm
Belt & jacketETFE, natural · belt OD 8.38 ± 0.18 mm · jacket OD 14.30 ± 0.28 mm
Embedded wiresGEEIPS steel wires, 2 layers in the outer ETFE jacket

Mechanical

Breaking strength80 kN18,000 lbf
Recommended working load32.3 kN7,250 lbf
Peak working load @ 0.90 % strain48.0 kN10,800 lbf
Wire min. break strength2.16 kN485 lbf
Recommended bend diameter29 cm11.5 in
Elongation (approx.)0.19 m/km/kN0.83 ft/kft/klbf
Unit weight, in air · fresh water≈ 594 · 433 kg/km†≈ 399 · 291 lb/kft

Electrical

Voltage, Element A (coax)900 Vdc
Voltage, Element B (power)1,200 Vdc
Element B / return · B / armour2,500 · 3,000 Vdc
R dc Element A, cdr · return40.3 · 27.2 Ω/km12.3 · 8.3 Ω/kft
R dc Element B · GEEIPS wires9.3 · 5.2 Ω/km2.8 · 1.6 Ω/kft
Insulation resistance @ 500 Vdc, A & B15,000 MΩ·km50,000 MΩ·kft

Optical

SMMM
Count22
Core / cladding9/125 µm PSC50/125 µm GI†
Coating · coated ODPolyimide · 155 µmPolyimide† · 155 µm
Proof test100 kpsi0.69 GPaTBC
Typical useDAS · BOTDR/A · FBG · DSSRaman DTS
  • Hybrid version of the retrievable wireline cable: a gel-filled 316L FIMT sits between two Element B conductors, halfway between the conductor layer and the inner GEEIPS layer, so belt, jacket, embedded wires, OD and all mechanical and electrical ratings are unchanged. Nominal values at 20 °C (68 °F).
  • † To be confirmed: FIMT size is limited by the inner GEEIPS wires at this position (max. OD ≈ 1.0 mm); MM fibre type, fibre attenuation and export / HTS classification to be confirmed; weights calculated from the base design + FIMT.
07Slickline · Downhole Fibre-Optic

Fibre-Optic Slickline Cable 6.35 × 0.71 mm · 316L | Alloy 825

Gel-filled FIMT with up to 6 hermetic fibres inside galvanized high-carbon steel strength wires · DTS / DAS-ready · retrievable · 29 kN rated · 180 °C (356 °F)

SL-FO-6.35x0.71Rev A · 15 Oct 2026
Fibre-Optic Slickline Cable — illustration
Illustration · Ø 6.35 mm · not to scale
Overall diameter6.35 mm0.250 in
Rated tensile strength29 kN6 520 lbf
Collapse pressure, tube138 MPa20 000 psi
Operating temperature−40 … +180 °C(−40 … +356 °F)

Applications

  • Distributed downhole monitoring (DTS, DAS)
  • Well logging
  • Retrievable downhole cable · slickline operation
  • Signal transmission from downhole tools

Construction

Protection tubeAISI 316L or UNS N08825 (Alloy 825) · OD 6.35 · wall 0.71 · ID 4.93 mm
Strength membersGalvanized high-carbon steel wires, single layer
Buffer layerHigh-temperature polymer · cushions the FIMT inside the wire layer
FIMTAISI 304 stainless · gel-filled · OD 1.8 / ID 1.4 mm
Optical fibresUp to 6 · SM(H) and/or MM(H) · hermetic, HT acrylate · e.g. 2 × SM(H) + 2 × MM(H)

Physical & mechanical

Weight in air · fresh water198 · 166 kg/km133 · 112 lb/kft
Rated tensile strength29 kN6 520 lbf
Max. operating tension14 kN3 150 lbf
Collapse pressure, tube138 MPa20 000 psi
Min. bend radius, no load160 mm6.3 in
Min. sheave Ø at max. tension660 mm26 in

Optical

SM(H)MM(H)
ITU-TG.652.D + G.657.A1G.651.1
Attenuation 1310 | 850 nm0.40 dB/km3.0 dB/km
Attenuation 1550 | 1300 nm0.26 dB/km1.1 dB/km
Max. temperature180 °C(356 °F)180 °C(356 °F)
  • Attenuation values are in-cable; local discontinuities caused by winding on the reel are permitted. Tube alloy and fibre count / mix per order (up to 6 fibres).

A Growing, Integrated DFOS Solution

Additional components are being introduced to provide a complete, integrated solution across the full sensing chain.

Downhole cable Surface connection Interrogation

Drop us a line

We’d love to hear from you. Whether you’re exploring DFOS solutions or need support for your current project, our team is ready to help.

Our Offices

United Arab Emirates
United Kingdom
Regional Offices

Address

United Arab Emirates
Office No. BC-892656, 26th Floor, Amber Gem Tower
Sheikh Khalifa Street, Ajman, United Arab Emirates
+971 58 880 5580
United Kingdom
20 Wenlock Road, London, England N1 7GU
+44 (0)20 3576 6692
Scroll to Top